Description
We have found that all query scripts are being automatically cancelled soon after starting the full run
Applies To
Studio, query
Cause
Tables utilized by Winshuttle query were not filled when the WFM was installed.
Solution/Immediate Workaround
- Go into the SAP environment directly (not via Winshuttle).
- Go into t-code SE38 and execute the program, /WINSHTLQ/TRN_UPGRADE_TABLE.
- On the next screen, execute this program for the following tables:
-/WINSHTLQ/TRCTAB
-/WINSHTLQ/QRSAOB
-/WINSHTLQ/QREPRM - Close all instances of Winshuttle Studio, then launch Studio and test the scenario once again.
Comments